Full-Scale Tests of Butt-Welded Splices in Heavy-Rolled Steel Sections Subjected to Primary Tensile Stresses
DOI:
https://doi.org/10.62913/engj.v28i1.570Abstract
Experimental results from full-scale testing of full and partial penetration butt-welded capacity. Qualitative explanations are given as to the cause of the observed failure. The splice with full penetration welds exhibited satisfactory strength and ductility. It is believed that a great amount of care must be taken in the execution of this weld type. Future research needs are examined.
Downloads
Published
03/31/1991
How to Cite
Bruneau, M., & Mahin, S. A. (1991). Full-Scale Tests of Butt-Welded Splices in Heavy-Rolled Steel Sections Subjected to Primary Tensile Stresses. Engineering Journal, 28(1), 1–17. https://doi.org/10.62913/engj.v28i1.570