Technical Note: Unbraced Length Requirements for Steel Special Cantilever Column Systems

Authors

  • Robert J. Walter
  • Chia-Ming Uang

DOI:

https://doi.org/10.62913/engj.v57i4.1169

Keywords:

AISC Seismic Provisions, steel special cantilever column system, bracing

Abstract

AISC Seismic Provisions Section E6.4b for steel special cantilever column systems (SCCS) requires clarification based on inquiries to the AISC Steel Solution Center. In the 2016 edition, it is unclear if bracing is required for all special cantilever columns or for columns with unbraced lengths that exceed the maximum beam brace spacing of Lb per Section D1.2a for moderately ductile members. Instead of using Equation D1-2, which is applicable to I-shaped beams only, equations for SCCS columns have been derived for both I-shaped members and rectangular HSS or box-shaped members. The proposed revision provides specific situations when bracing is required.

Downloads

Published

12/31/2020

How to Cite

Walter, R. J., & Uang, C.-M. (2020). Technical Note: Unbraced Length Requirements for Steel Special Cantilever Column Systems. Engineering Journal, 57(4), 243–245. https://doi.org/10.62913/engj.v57i4.1169

Most read articles by the same author(s)